Note :If Driven Pressure (PD) is 6
kg/cm2, Supply Pressure (PS) is 6 kg/cm2 pressure, the 『Per minute PH of output』and 『Driven pressure consumption by cycle』the resulting values in the form described.
For example: When High Pressure Gas
Booster specifications for PW100025, in the PD is 6 kg/cm2 and PS is 6 kg/cm2
pressure, the 『Per minute PH of output』of calculated values are: 20 l/min;
Additionally 『Driven pressure consumption by cycle』of calculated values to 10.8L.